Jul 26, 2026 D-PSC-DS-01 Exam Crack Test Engine Dumps Training With 360 Questions [Q199-Q217]

Share

Jul 26, 2026 D-PSC-DS-01 Exam Crack Test Engine Dumps Training With 360 Questions

Obtain the D-PSC-DS-01 PDF Dumps Get 100% Outcomes Exam Questions For You To Pass

NEW QUESTION # 199
A customer plans to migrate data to a remote Isilon cluster.
What is a consideration when configuring a cluster with SyncIQ and hard SmartQuotas?

  • A. Quotas should be configured on both SyncIQ source and target directories prior to a migration.
  • B. Quotas should be set only on source directories and never on target directories for migrations.
  • C. SyncIQ will replicate source quota configurations to the target.
  • D. SyncIQ ignores quota limits during replication but if a quota is over limit, quotas will still allow users to add data to the directory.

Answer: D


NEW QUESTION # 200
What is the best case performance for Backup Accelerator when backing up to LTO-4 or LTO-5 drives?

  • A. 2.6 TB/hr
  • B. 3.4 TB/hr
  • C. 1.7 TB/hr
  • D. 864 GB/hr

Answer: A


NEW QUESTION # 201
What advantage does journaling provide in OneFS?

  • A. It performs inline deduplication of transaction logs
  • B. It reduces file system recovery times after unexpected shutdowns
  • C. It records all network traffic for auditing purposes
  • D. It automatically generates compliance snapshots for regulatory workflows

Answer: B


NEW QUESTION # 202
On an eight node Gen 6 cluster, how are files greater than 128 KB protected?

  • A. 2x mirrored
  • B. N+2d:1n
  • C. N+3d:1n
  • D. 3x mirrored

Answer: B


NEW QUESTION # 203
A system administrator notices isi_gather_info takes a long time to complete.
How can the next run be optimized?

  • A. Exclude non-essential tools from the gathering process
  • B. Restart the CELOG daemon
  • C. Collect logs only from the syslog server
  • D. Increase the speed of the network link

Answer: A


NEW QUESTION # 204
A company wants to restrict each department's storage usage to no more than 1.2 TB, while also alerting them when usage exceeds 1 TB.
Which type of quota should be configured on the PowerScale cluster?

  • A. Enforced quota
  • B. Soft quota
  • C. Hard quota
  • D. Advisory quota

Answer: C


NEW QUESTION # 205
What are valid uses of iostat and netstat in PowerScale design validation? (Select all that apply)

  • A. Validating SmartConnect DNS delegation
  • B. Evaluating network interface performance and socket connections
  • C. Measuring disk I/O performance at the operating system level
  • D. Automatically adjusting file pool policies for tiering

Answer: B,C


NEW QUESTION # 206
During a write process in OneFS 8.0, from which cache are blocks copied to disk?

  • A. L2
  • B. L3
  • C. Endurant
  • D. L1

Answer: C


NEW QUESTION # 207
Refer to the exhibit.

Which tool was used to create this output and which line item counts the metadata read operations occurring in the file service?

  • A. isi_netlogger and commit
  • B. tcpdump and nfsstat
  • C. nfsstat and getattr
  • D. iostat and fsstat

Answer: C


NEW QUESTION # 208
You meet a customer for the first time. They explain that their current environment for NAS does not meet their needs. You want to make sure that Isilon is a good fit for their needs.
What would be a good prequalifying question to ask?

  • A. What application are you using to create directories?
  • B. What protocols are accessing your NAS?
  • C. Is your datacenter ISO9001 compliant?
  • D. How many users are in your Directory Services?

Answer: B


NEW QUESTION # 209
What is the threshold for a file to be considered small on a PowerScale Gen6 cluster?

  • A. 128 KB
  • B. 8 KB
  • C. 256 KB
  • D. 64 KB

Answer: A


NEW QUESTION # 210
You are adding a new node to an existing cluster.
What OneFS function should you use to remove the old nodes from the cluster?

  • A. SmartPools
  • B. SmartFail
  • C. SyncIQ
  • D. AutoBalance

Answer: B


NEW QUESTION # 211
During initial configuration of a PowerScale cluster, OneFS creates a network using the default internal network interface without a failover option.
What is the default back-end network interface used?

  • A. eth-0
  • B. int-a
  • C. eth-1
  • D. int-b

Answer: B


NEW QUESTION # 212
In OneFS, what is the largest number of disks in a subpool?

  • A. 0
  • B. 1
  • C. 2
  • D. 3

Answer: B


NEW QUESTION # 213
A solutions architect is asked to configure Continuous Availability to an existing PowerScale SMB share.
How can the task can be accomplished?

  • A. Re-create the share and enable CA.
  • B. Disable the share and enable CA.
  • C. Stop all SMB shares and globally enable CA.
  • D. Enable CA from the properties section of the share.

Answer: A


NEW QUESTION # 214
What is the recommended best practice for time synchronization on a PowerScale cluster?

  • A. Use NTP for both the cluster and the Domain Controller.
  • B. Enable both SMB time sync and NTP equally for all nodes.
  • C. Disable NTP and rely only on SMB time synchronization.
  • D. Use SMB time synchronization by default and NTP for Domain Controllers.

Answer: A


NEW QUESTION # 215
An Isilon customer is experiencing less than expected performance and poor space utilization with their cluster. They are using the X400 nodes with an N+2d:1n protection policy to host web server log data.
Upon further analysis, the customer discovers that the web servers write log files 64KiB in size. The log files are then accessed by an analytics application for reporting purposes.
What should be done to increase the write performance of the cluster?

  • A. Change the SSD strategy on the cluster
  • B. Add S-Series storage nodes to the cluster
  • C. Change the protection scheme to a mirroring policy
  • D. Add A-Series Performance Accelerator nodes to the cluster

Answer: D


NEW QUESTION # 216
You are sizing a PowerScale Gen6 cluster for a small organization that is concerned about the availability of the journal during an extended power outage.
What is a consideration when sizing?

  • A. Journal is written to nonvolatile storage if power is lost.
  • B. Battery life within each node is a limiting factor.
  • C. Journal is replicated to all nodes within a chassis.
  • D. Journal must be protected by an external UPS.

Answer: A


NEW QUESTION # 217
......

D-PSC-DS-01 Exam Dumps Contains FREE Real Quesions from the Actual Exam: https://passguide.testkingpass.com/D-PSC-DS-01-testking-dumps.html